P20
The application of conformal coatings over no clean flux is a common practice. The user should perform adequate testing to confirm compatibility between the conformal coating and their particular assembly materials and process conditions. Please contact H
Specifications
Aerosol is a fast drying, clear urethane conformal coating intended for use on printed circuit assemblies. The product is conveniently dispensed from aerosol cans, utilizing an environmentally safe, non-ODP propellant. The coating may be removed chemically using .
Applications
Allow 48 hours minimum to reach room temperature before using cans stored or received during cold weather.
When applied in conditions of high ambient humidity, blushing (cloudy white film) may appear. Heating the coated assembly in an oven for 1/2 hour at 76°C eliminates this condition.
Cleanliness of the substrate is extremely important to the successful application of a conformal coating. Surfaces should be free of moisture, dirt, wax, grease and all other contaminants. Otherwise, ionic or organic residues on the substrate could be trapped under the coating and cause problems with adhesion or electrical properties. The highest long term reliability for a coated printed circuit assembly will be when the conformal coating is applied over a clean, dry substrate.**
Mask areas not requiring coating from overspray using suitable non-silicone masking methods or materials.
Shake can vigorously before using and repeat frequently during use.
Best results are obtained by spraying from a distance of 30 – 40cm in light even coats. A film thickness of 25 – 75 microns is sufficient to provide protection.
To clean nozzle after use, hold can upside down, then press nozzle for a few seconds.
The application of conformal coatings over no clean flux is a common practice. The user should perform adequate testing to confirm compatibility between the conformal coating and their particular assembly materials and process conditions. Please contact HumiSeal for additional information.
Caution
ApplicationConformal Coatings should be carried out in accordance with local and National Health and Safety regulations.
The solvents in Conformal Coatings are flammable. Material should not be used in presence of open flame or sparks. Use only in well-ventilated areas to avoid inhalation of vapours or spray. Avoid contact with skin and eyes.